Cables using physical foam insulation technology have a nominal impedance of 75 ohms and comply with EN 50117. They are primarily used in cable TV, individual/central satellite distribution and CCTV security camera systems.
Balenie: 100m
Operating Temperature | -30 °C ... +70 °C |
Bending radius min. | 10 x D |
Impedance | 75 ? 3 ? |
Capacitance | 52 ? 2 pF/m |
Velocity of propagation | %84 ? 2 |
Insulation resistance min. | 2 G ? x km |
Operating voltage max. | 1300 V |
Test voltage | 3000 V |
Standards | EN 50117, IEC 61196 |
Fire performans | Vertical flame spread EN 60332-1-2 |
Satellite distribution2) | 2150MHz - 60m |
VHF/UHF distribution3) | 860MHz - 150m |
S-band Cable TV distribution3) | 470MHz - 210m |
Attenuation @20°C max | 50 MHz 4.74 dB/100m 200 MHz 9.29 dB/100m 470 MHz 14.35 dB/100m 860 MHz 19.72 dB/100m 1000 MHz 21.37 dB/100m 2150 MHz 32,52 dB/100m 2400 MHz 34.59 dB/100m 3000 MHz 39.26 dB/100m |
Return Loss | 5-470 MHz > 20 dB 470-1000MHz > 18 dB 1000-2000 MHz > 16 dB 2000-3000 MHz > 15 dB |
Screen Attenuation | 30-1000 MHz ? 75 dB 1000-2000MHz ? 65 dB 2000-3000 MHz ? 55 dB |
Transfer Impedance | 5-30 MHz ? 15 m?/m |
Výrobca | Recber |
Materiál vonkajšej izolácie | PVC |
Materiál vnútorného vodiča | Cu meď |
Tienenie kábla | Celomedené |
Priemer kábla | 6,8 mm |
Nehorľavé - Bezhalogénové | NIE |